可靠的EMC D-XTR-MN-A-24考試內容是行業領先材料&免費PDF D-XTR-MN-A-24學習資料

Tags: D-XTR-MN-A-24考試內容, D-XTR-MN-A-24學習資料, D-XTR-MN-A-24考試備考經驗, D-XTR-MN-A-24題庫最新資訊, D-XTR-MN-A-24題庫資料

Fast2test 就是一個能使 D-XTR-MN-A-24 認證考試的通過率提高的一個網站。我們的資深IT專家在不斷研究出各種成功通過 EMC D-XTR-MN-A-24 認證考試的方案,他們的研究成果可以100%保證一次性通過 EMC D-XTR-MN-A-24 認證考試。在我們的支援下,您不但能順利通過考試,還能節省了時間和金錢。此外,我們承諾如果不通過 D-XTR-MN-A-24 考試,將100%退款。

EMC D-XTR-MN-A-24 考試大綱:

主題簡介
主題 1
  • XtremIO and X2 Hardware Fundamentals: Storage engineers and system architects will find this section particularly relevant. It delves into hardware design descriptions, IB switch options, and BBU options including SuperCap. The exam also covers DAE capacities and XtremIO X2 configurations and port management, providing a comprehensive understanding of the hardware components and their functionalities.
主題 2
  • XtremIO and X2 Maintenance: The largest section of the exam is dedicated to maintenance, targeting storage maintenance technicians and support personnel. It covers resource identification, power procedures, and methods for determining cluster health state and failure tolerances for components. The section also includes cluster IP address modification and Storage Controller FRU, providing a comprehensive overview of ongoing maintenance and troubleshooting procedures.
主題 3
  • XtremIO and X2 Installation: This section is tailored for storage implementation specialists and field engineers. It encompasses installation resource requirements, component racking for both single and dispersed cluster setups and detailed cabling procedures for single and multi X-Brick clusters.
主題 4
  • Overview of XtremIO and X2 Features: For storage administrators and technical specialists, this section of the exam covers the comparison of XtremIO and X2 capabilities, GUI differences between the two systems with a focus on X2 updates, and the identification of XtremIO and X2 models. This foundational knowledge is crucial for understanding these storage solutions' core features and distinctions.
主題 5
  • XtremIO and X2 Initial Configuration: System administrators and configuration specialists will focus on this section, which covers the deployment and options for the XtremIO Management Server (XMS). It also includes Easy-CLI installation options, XtremApp installation, cluster installation, and verification, and the configuration of ESRS and ESRS VE.

>> D-XTR-MN-A-24考試內容 <<

高水準的D-XTR-MN-A-24考試內容,最好的學習資料幫助妳壹次性通過D-XTR-MN-A-24考試

如果你正在準備 D-XTR-MN-A-24 考試,為 D-XTR-MN-A-24 認證做最後衝刺,又苦於沒有絕對權威的考試真題模擬。很多考生現在都用 EMC D-XTR-MN-A-24 考題作為參加D-XTR-MN-A-24 考試最快捷,最信任的方式。擺正好心態,認真閱讀准備好的 D-XTR-MN-A-24 考題,考試時心中不要慌,任何一場考試,都是與考生在進行心理戰的准備,遇到難的題目先不要去管,調整好心態准備應戰下一條題目。加上之前准備充足獲取 D-XTR-MN-A-24 認證應該是沒有問題的。

最新的 Storage Administrator D-XTR-MN-A-24 免費考試真題 (Q10-Q15):

問題 #10
What must be submitted with an RPQ prior to a dispersed XtremlO cluster installation?

  • A. Cabling kits and X-Brick component location diagram
  • B. Wiring diagram and X-Brick component location diagram
  • C. Cabling kits and list of allowed deviations from the RPQ
  • D. Wiring diagram and list of cables needed for the cluster

答案:B

解題說明:
When submitting a Request for Product Qualification (RPQ) prior to a dispersed XtremIO cluster installation, it is necessary to include a wiring diagram and an X-Brick component location diagram. The wiring diagram provides a detailed representation of the electrical connections between the components, while the X-Brick component location diagram shows the physical placement of the X-Brick components within the installation environment. These documents are essential for planning the installation to ensure that all components are correctly positioned and connected for optimal performance and serviceability1.
The process for preparing these documents typically involves:
Creating a detailed wiring diagram that outlines all the necessary connections between the X-Brick components and other infrastructure elements.
Developing an X-Brick component location diagram that illustrates where each component will be physically located in the data center.
Reviewing the diagrams to ensure they meet the technical requirements and specifications for a dispersed XtremIO cluster installation.
Submitting the diagrams along with the RPQ for approval before proceeding with the installation.
These steps are crucial for a successful installation and are outlined in the Official Dell XtremIO Maintenance Achievement document1.


問題 #11
On XtremlO X1, what is required before the cluster will start?

  • A. BBUs must be charged to at least 70%
  • B. BBUs must be charged to at least 50%
  • C. At least one BBU has to be online
  • D. End of Life BBUs must be replaced

答案:A

解題說明:
Before an XtremIO X1 cluster can start, it is required that the Battery Backup Units (BBUs) are charged to at least 70%. This ensures that there is sufficient power reserve to maintain data integrity and allow for safe shutdown procedures in case of an unexpected power loss. The BBUs provide power to the Storage Processors and other critical components during an outage, allowing them to complete any in-progress operations and commit data to SSDs1.
The startup process checks the BBU charge level and will only proceed if the minimum charge requirement is met. This is a safety feature designed to protect the system and the data it holds. If the BBUs are not adequately charged, the system will not start, preventing potential data loss or corruption that could occur if the system were to lose power without the ability to properly shut down1.


問題 #12
A multi X-Brick XtremlO X1 cluster is being installed. How many BBU connections, and of which type, are required per X-Brick?

  • A. 1 BBU providing protective power to the Storage Controllers
    2 BBU COM ports; one connected to each Storage Controller
  • B. 1 BBU providing protective power to the bottom Storage Controller
    2 BBU COM ports; one connected to each Storage Controller
  • C. 2 BBUs providing protective power to X-Brick 1 and 2 Storage Controllers only
    4 BBU COM ports connected to each Storage Controller
  • D. 2 BBUs providing protective power to the Storage Controllers
    1 BBU COM port connected to the bottom Storage Controller

答案:A

解題說明:
For a multi X-Brick XtremIO X1 cluster, each X-Brick requires one Battery Backup Unit (BBU) that provides protective power to both Storage Controllers within the X-Brick. Additionally, there are two BBU COM (communication) ports required, with one connected to each Storage Controller. This configuration ensures that in the event of a power failure, the BBU can maintain power to the Storage Controllers, allowing them to safely shut down and protect data integrity1.
The installation process would typically involve:
Installing the BBU in the designated slot within the X-Brick.
Connecting the BBU power cable to the power supply of both Storage Controllers.
Connecting a BBU COM port to each Storage Controller for communication and monitoring purposes.
This setup is crucial for maintaining the high availability and data protection standards that XtremIO systems are known for1.


問題 #13
What is the correct sequence of steps to power up an XtremlO X1 cluster after an emergency shutdown?

答案:

解題說明:

1 - Determine the cause of the shutdown
2 - Power up the Battery Backup Units
3 - Power up the XMS
4 - Power up the Storage Controllers
5 - Start the cluster


問題 #14
What is the impact of a serial cable failure in a multi X-Brick XtremIO X1 cluster?

  • A. Failure of more than half of the COM cables forces the cluster into a degraded mode
  • B. Failure of one serial cable makes the BBU not visible to the cluster's environment monitoring
  • C. Failure of more than half of the BBU COM cables results in a loss of service
  • D. Failure of one COM cable results in a loss of service

答案:A

解題說明:
In a multi X-Brick XtremIO X1 cluster, the failure of more than half of the COM (communication) cables forces the cluster into a degraded mode. This degraded mode is a protective measure to ensure that the cluster can continue operating with reduced performance and redundancy until the issues with the COM cables are resolved.


問題 #15
......

為了對你們有更多的幫助,我們Fast2test EMC的D-XTR-MN-A-24可在互聯網上消除這些緊張的情緒,D-XTR-MN-A-24學習材料範圍從官方EMC的D-XTR-MN-A-24認證培訓課程EMC的D-XTR-MN-A-24自學培訓指南,Fast2test的D-XTR-MN-A-24考試和實踐,D-XTR-MN-A-24線上考試,D-XTR-MN-A-24學習指南, 都可在網上。我們Fast2test設計的D-XTR-MN-A-24模擬培訓包,可以幫助你毫不費力的通過考試,現在你不要花太多的時間和金錢,只要你擁有了本站的學習資料,只要按照指示,關注於考試的問題,你將很容易的獲得認證。

D-XTR-MN-A-24學習資料: https://tw.fast2test.com/D-XTR-MN-A-24-premium-file.html

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Comments on “可靠的EMC D-XTR-MN-A-24考試內容是行業領先材料&免費PDF D-XTR-MN-A-24學習資料”

Leave a Reply

Gravatar